Ram Cold Tar® Plus
RESTORATION & ROOF RECOVERY SYSTEM
DESCRIPTION
RAM Cold Tar® Plus can extend the service life of an existing bituminous roof for many years and reducing both the life cycle cost of the original roof and the energy usage of the building as a whole.
Using the existing bituminous roof mat as a substrate, RAM Cold Tar® Plus fuses a new, high-strength, fluid-applied rubbery membrane to the mass of the old roof mat, creating a new, double thick, elastomeric waterproof membrane. RAM Cold Tar® Plus is a coal tar pitch fortified, thermoplastic SEBS polymerized surfacing compound that is specially formulated to adhere to asphalt, modified bitumen, and coal tar roofing systems. RAM Cold Tar® Plus has the ability to resist standing water. An economical alternative to re-roofing, RAM Cold Tar® Plus can save 40-60% of full roof replacement costs.
-
TECHNOLOGY
Thermoplastic SEBS Polymer-Modified
-
MATERIAL
Rubberized Adhesive Coating
-
APPLICATION
Cold Fluid Applied
-
INSTALLATION
Single Component
Ram Cold Tar® Plus (1st Coat)
Ram Cold Tar® Plus | Rubberized Adhesive Coating(1st Coat)
Ram Cold Tar® Plus (2nd Coat)Ram Cold Tar® Plus | Rubberized Adhesive Coating(2nd Coat)
Ram 40Ram 40 | Polyester/Fiberglass Reinforcement
Ram Ultra-White®Ram Ultra-White® | Energy-Star® Acrylic Roof Coating
Ram Cold Tar® Plus
RESTORATION & ROOF RECOVERY SYSTEM
PROPERTIES | MEASUREMENT | TEST METHOD |
---|---|---|
Water | 0.5% or less | ASTM D-95 |
Non-Volatile Content | 62 - 64% | ASTM D-6511 |
Mineral and/or other Stabilizers | 3.79% | ASTM D-4 |
Workability | Pass | ASTM D-6511 |
Pliability (at 32°F) | Pass | ASTM D-6511 |
Viscosity | 10,000 - 15,000 cps | ASTM D-2196 |
Density | 7.9 lbs/gal | ASTM D-1475 |
Tensile Strength | 190 psi (min) | ASTM D-412 |
Elongation (at 77°F) | >2000% | ASTM D-412 |
Elongation (at -40°F) | 472% | ASTM D-412 |
Low Temperature Flexibility (at 76°F) | Pass | ASTM D-5147 |